APC Smart-UPS VT, 24 kW / 30 kVA,Input 400V 3PH / Output 230V, 400V 3PH, Interface Port DB-9 RS-232, Smart-Slot, Extended runtime model. Includes: Battery modules ship installed, Bolt down brackets, CD with software, Installation guide, Network Management Card, Power modules ship installed, Start up included, User Manual. - Parallel-capacity capable Increases total power capacity by using multiple UPSs simultaneously. - Parallel-redundant capable Power the connected equipment with multiple UPSs to increase system redundancy Availability - Dual mains input Increases availability by allowing the UPS to be connected to two separate power sources. - Scalable runtime Allows additional run time to be quickly added as needed. - Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced - Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used. - Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault. - Battery modules connected in parallel Delivers higher availability through redundant batteries.
Serviceability - User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) - Battery replacement without tools Allows quick, easy battery replacement. - Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. - Shippable with modules installed Enables pre-installation UPS staging and testing and faster installation. - Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Manageability - Network manageable Provides remote management of the UPS over the network. - InfraStruXure Manager Compatible Enables centralized management via the APC InfraStruXure Manager. - LCD display Alpha-Numeric Display which displays system parameters and alarms. - Audible alarms Provides notification of changing utility power and UPS conditions. - Programmable frequency Ensures compatibility with different input frequencies. - LED status indicators Quickly understand unit and power status with visual indicators. - SmartSlot Customize UPS capabilities with management cards.
Total Cost of Ownership - Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling. - Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. - Manual maintenance bypass Reduces installation costs by eliminating the need for an external mechanical bypass. - Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
Protection - Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. - Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. - Cold-start capable Provides temporary battery power when the utility power is out.
Products specifications
Attribute name | Attribute value |
---|
Weight | 1386.9 lbs |
Battery Type | Black |
Input Frequency | LCD |
Battery Recharge Time | 5 h |
Emergency Power Off (EPO) | Y |
Certification | C-tick,CE,EN 50091-2,EN/IEC 62040-3,IEC 61000-3-2,IEC 61000-3-3,ISO 14001,ISO 9001,VFI-SS-112 |
Product color | Black |
Output power | 24000 W |
Noise level | 55 dB |
Dimensions (WxDxH) | 22 x 32 x 59" |
Package weight | 1455.1 lbs |
Output connections | 1 x Hard Wire 4-wire (3PH + G) 1 x Hard Wire 5-wire (3PH + N + G) 1 x Screw Terminals |
Package dimensions (WxDxH) | 25.6 x 41.8 x 64.7" |
Input connection type | Hard Wire 5-wire (3PH + N + G) |
Maximum current | 41 A |
Nominal input voltage | USB cable |
Output power capacity | 30 kVA |
Operating altitude | 0 - 590551.2" |
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -15 - 45 °C |
Operating relative humidity (H-H) | 0 - 95 % |
Storage relative humidity (H-H) | 0 - 95 % |
Non-operating altitude | 0 - 590551.2" |
Replacement battery cartridge | 4 |