APC SURT20KRMXLT-TF5 uninterruptible power supply (UPS) 20 kVA 18 AC outlet(s)

APC SURT20KRMXLT-TF5. Output power capacity: 20 kVA, Input operation voltage (min): 160 V, Input operation voltage (max): 280 V. AC outlet types: NEMA 5–20R, NEMA L6-20R, NEMA L6-30R, AC outlets quantity: 18 AC outlet(s). Battery technology: Sealed Lead Acid (VRLA), Battery recharge time: 2.50 h. Form factor: Rackmount/Tower, Product color: Black, Rack capacity: 14U. Width: 17" (432 mm), Depth: 30.4" (773 mm), Height: 24.5" (622 mm)
Manufacturer: APC
SKU: 2702587
Manufacturer part number: SURT20KRMXLT-TF5
MSRP: $36,690.00
$30,734.36
LCD display
Alpha-Numeric Display which displays system parameters and alarms.

Removable input/output wiring tray
Allows quick and easy installation and maintenance of the UPS.

Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

Manageable external batteries
Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.

Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.

Scalable runtime
Allows additional run time to be quickly added as needed.

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.

Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.

Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.

Network manageable
Provides remote management of the UPS over the network.

InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.

SmartSlot
Customize UPS capabilities with management cards.

LED status indicators
Quickly understand unit and power status with visual indicators.

Serial Connectivity
Provides management of the UPS via a serial port.

Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.

Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP.

User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.

Disconnected battery notification
Warns when a battery is not available to provide backup power.

Audible alarms
Provides notification of changing utility power and UPS conditions.

Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.

Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.

Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.

Cold-start capable
Provides temporary battery power when the utility power is out.

Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
LCD display
Alpha-Numeric Display which displays system parameters and alarms.

Removable input/output wiring tray
Allows quick and easy installation and maintenance of the UPS.

Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

Manageable external batteries
Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.

Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.

Scalable runtime
Allows additional run time to be quickly added as needed.

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.

Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.

Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.

Network manageable
Provides remote management of the UPS over the network.

InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.

SmartSlot
Customize UPS capabilities with management cards.

LED status indicators
Quickly understand unit and power status with visual indicators.

Serial Connectivity
Provides management of the UPS via a serial port.

Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.

Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP.

User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.

Disconnected battery notification
Warns when a battery is not available to provide backup power.

Audible alarms
Provides notification of changing utility power and UPS conditions.

Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.

Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.

Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.

Cold-start capable
Provides temporary battery power when the utility power is out.

Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Products specifications

Attribute name Attribute value
Weight 641.3 lbs
Number of phases 2
Height 100-240 V
EMI/RFI noise filtering 59 dB
Filtering description 0.3% IEEE
Depth 30.4"
Battery Recharge Time 2.50 h
Input current Total Harmonic Distortion (THD) 5 %
Width 17"
Input Frequency 50/60 Hz
Display LCD
Display Type LCD
Crest factor 3:1
Emergency Power Off (EPO) Yes
Cold start Yes
Over current protection Yes
Design
Certification UL 1778
Form factor Rackmount/Tower
Technical details
Networking features 10/100 Base-T
Product color Black
Features
Rack capacity 14U
Input operation voltage (min) 160 V
Output operation voltage (min) 120 V
Output operation voltage (max) 208 V
Output voltage Total Harmonic Distortion (THD) 5 %
Input operation voltage (max) 280 V
Efficiency 94 %
LED indicators Yes
Audible alarm(s) Yes
Overload protection Yes
Weight & dimensions
Dimensions (WxDxH) 17 x 30.4 x 24.5"
Packaging data
Package weight 803.1 lbs
Other features
Package dimensions (WxDxH) 24 x 39.5 x 49"
Nominal output voltage 120-208 V
Ports & interfaces
Interface DB-9 RS-232, RJ-45, Smart-Slot
Serial ports quantity 3
AC outlets quantity 18 AC outlet(s)
Ethernet LAN (RJ-45) ports 1
RS-232 ports 1
AC outlet types NEMA 5–20R, NEMA L6-20R, NEMA L6-30R
Power
Maximum current 105 A
Output power capacity 20 kVA
Nominal input voltage 208 V
Power protection features Overload
Operational conditions
Operating temperature (T-T) 32 - 104 °F
Storage temperature (T-T) -15 - 45 °C
Operating relative humidity (H-H) 0 - 95 %
Storage relative humidity (H-H) 0 - 95 %
Operating altitude 0 - 118110.2"
Non-operating altitude 0 - 590551.2"
Battery
Battery technology Sealed Lead Acid (VRLA)
Number of battery cells 4
*
*
*

Products specifications

Attribute name Attribute value
Weight 641.3 lbs
Number of phases 2
Height 100-240 V
EMI/RFI noise filtering 59 dB
Filtering description 0.3% IEEE
Depth 30.4"
Battery Recharge Time 2.50 h
Input current Total Harmonic Distortion (THD) 5 %
Width 17"
Input Frequency 50/60 Hz
Display LCD
Display Type LCD
Crest factor 3:1
Emergency Power Off (EPO) Yes
Cold start Yes
Over current protection Yes
Design
Certification UL 1778
Form factor Rackmount/Tower
Technical details
Networking features 10/100 Base-T
Product color Black
Features
Rack capacity 14U
Input operation voltage (min) 160 V
Output operation voltage (min) 120 V
Output operation voltage (max) 208 V
Output voltage Total Harmonic Distortion (THD) 5 %
Input operation voltage (max) 280 V
Efficiency 94 %
LED indicators Yes
Audible alarm(s) Yes
Overload protection Yes
Weight & dimensions
Dimensions (WxDxH) 17 x 30.4 x 24.5"
Packaging data
Package weight 803.1 lbs
Other features
Package dimensions (WxDxH) 24 x 39.5 x 49"
Nominal output voltage 120-208 V
Ports & interfaces
Interface DB-9 RS-232, RJ-45, Smart-Slot
Serial ports quantity 3
AC outlets quantity 18 AC outlet(s)
Ethernet LAN (RJ-45) ports 1
RS-232 ports 1
AC outlet types NEMA 5–20R, NEMA L6-20R, NEMA L6-30R
Power
Maximum current 105 A
Output power capacity 20 kVA
Nominal input voltage 208 V
Power protection features Overload
Operational conditions
Operating temperature (T-T) 32 - 104 °F
Storage temperature (T-T) -15 - 45 °C
Operating relative humidity (H-H) 0 - 95 %
Storage relative humidity (H-H) 0 - 95 %
Operating altitude 0 - 118110.2"
Non-operating altitude 0 - 590551.2"
Battery
Battery technology Sealed Lead Acid (VRLA)
Number of battery cells 4

Product tags

  • (52290)
/* Added for Digitol */ /* End Added for Digitol */