CyberPower PDU30SWHVT19ATNET power distribution unit (PDU) 19 AC outlet(s) 2U Black

CyberPower PDU30SWHVT19ATNET. PDU types: Switched, Rack capacity: 2U, Product color: Black. AC outlets quantity: 19 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, NEMA L6-30R. Cable length: 118.1" (3 m), Certification: UL60950_1 certified by ETL (USA), CSA C22.2 (Canada), FCC Class A. Management platform: SNMP/HTTP. Nominal input voltage: 200-240 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz
Manufacturer: CyberPower
SKU: 4093500
Manufacturer part number: PDU30SWHVT19ATNET
UPC: 649532610914
$919.95
The CyberPower PDU30SWHVT19ATNET, 19-outlet 2U rack mount switched auto transfer switch (ATS) power distribution unit (PDU), provides 200-240V / 30A output. The PDU distributes unfiltered electrical pass-through to 1 NEMA L6-30R, 18 IEC-320 (16) C13 / (2) C19 receptacles from redundant NEMA L6-30P plugs. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. The PDU30SWHVT19ATNET includes a SNMP/HTTP card (RMCARD203). With the SNMP card and an IP address on the network interface, users have real-time monitoring and outlet control of the ATS PDU. The switched outlet receptacles can be managed individually or collectively over the network the CyberPower Management Console /web browser and the RJ45 Ethernet port for network connection or, locally, using the LCD controls. Using the CyberPower Management Console, outlets can be turned on, turned off, or recycled on demand or at programmed times, to address multiple needs, including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads. Additionally, the CyberPower Management Console provides real-time remote monitoring of PDU vitals and event logging to review historical power conditions, such as input voltages, load levels, and outlet status. Automatic event notifications can be sent to designated users when power events occur, via Email, SMS Text, or SNMP Trap. The LCD provides local monitoring of the PDU and on/off control the outlets. Perform load management by using the display to measure the electrical current (displayed in amperes) used by connected equipment. The LCD can also display input and output voltages, to diagnose potential issues with input AC power. Active power consumption (displayed in kilowatts) and hardware and firmware versions are also viewable on the LCD screen. Designed for datacenters and other demanding electrical applications, the PDU30SWHVT19ATNET has a rugged, industrial-grade metal housing, a 10-foot AC power cord, and a cord retention tray. It can be mounted either horizontally and is UL60950_1 and CSA C22.2 certified by ETL and FCC Class A certified. A three-year warranty ensures that this PDU is free of defects in design, assembly, material or workmanship.
The CyberPower PDU30SWHVT19ATNET, 19-outlet 2U rack mount switched auto transfer switch (ATS) power distribution unit (PDU), provides 200-240V / 30A output. The PDU distributes unfiltered electrical pass-through to 1 NEMA L6-30R, 18 IEC-320 (16) C13 / (2) C19 receptacles from redundant NEMA L6-30P plugs. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. The PDU30SWHVT19ATNET includes a SNMP/HTTP card (RMCARD203). With the SNMP card and an IP address on the network interface, users have real-time monitoring and outlet control of the ATS PDU. The switched outlet receptacles can be managed individually or collectively over the network the CyberPower Management Console /web browser and the RJ45 Ethernet port for network connection or, locally, using the LCD controls. Using the CyberPower Management Console, outlets can be turned on, turned off, or recycled on demand or at programmed times, to address multiple needs, including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads. Additionally, the CyberPower Management Console provides real-time remote monitoring of PDU vitals and event logging to review historical power conditions, such as input voltages, load levels, and outlet status. Automatic event notifications can be sent to designated users when power events occur, via Email, SMS Text, or SNMP Trap. The LCD provides local monitoring of the PDU and on/off control the outlets. Perform load management by using the display to measure the electrical current (displayed in amperes) used by connected equipment. The LCD can also display input and output voltages, to diagnose potential issues with input AC power. Active power consumption (displayed in kilowatts) and hardware and firmware versions are also viewable on the LCD screen. Designed for datacenters and other demanding electrical applications, the PDU30SWHVT19ATNET has a rugged, industrial-grade metal housing, a 10-foot AC power cord, and a cord retention tray. It can be mounted either horizontally and is UL60950_1 and CSA C22.2 certified by ETL and FCC Class A certified. A three-year warranty ensures that this PDU is free of defects in design, assembly, material or workmanship.
*
*
*