Tripp Lite PDU3EVSR6H50 power distribution unit (PDU) 30 AC outlet(s) 0U Black

Tripp Lite PDU3EVSR6H50. PDU types: Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 30 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: CS8365C. Cable length: 72" (1.83 m), Certification: Tested to UL60950-1: 2007 R10.14 (USA), CAN/CSA-C22.2 NO. 60650-1-07+A1: 2011+A2: 2014 (Canada).... Monitoring: Current, Humidity, Power, Temperature, Outlet control: Lock-out, Recycle, Turn off, Turn on, Supported network protocols: HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP. Nominal input voltage: 200-240 V, Maximum current: 35 A, AC input frequency: 50 - 60 Hz
Manufacturer: Tripp Lite
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: 5070545
Manufacturer part number: PDU3EVSR6H50
UPC: 0037332195388
MSRP: $2,433.00
$1,760.55
The PDU3EVSR6H50 14.5kW 3-Phase Switched Power Distribution Unit provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for any IT or industrial application, it features 30 switched outlets (24 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A six-foot cord with Hubbell CS8365C plug connects the PDU to a compatible AC power source, generator or protected UPS. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. A color touchscreen LCD lets you toggle between menus to monitor input current level per phase, output current per load bank and per outlet with ±1% billing-grade accuracy, environmental sensor data and network information. It also generates a unique QR code to allow access to the switchable PDU through a mobile device. The 0U PDU mounts vertically in racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.
Distributes, Monitors and Manages Network-Grade AC Power - 14.5kW 200/208/240V switched PDU with 3-phase input - Recommended for network applications requiring individual outlet control, load shedding and remote monitoring of critical network components - Hubbell CS8365C plug with 6 ft. cord connects to compatible AC power source - Firmware upgrades support future product enhancements 30 Switched Outlets Distribute AC Power - 24 C13 and 6 C19 outlets split into 3 separately breakered load banks - Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices - Plug-lock insert sleeves prevent cables from becoming accidentally disconnected Color Touchscreen LCD - Reports network data, including IP address, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy - Generates unique QR code for read-only access to PowerAlert® Device Manager via mobile device - Full access available by logging into PowerAlert Device Manager via browser as user with read/write credentials Built-In LX Platform Interface - Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH - Supports 10/100 Mbps auto-sensing for communication with an Ethernet network - Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities - No Java required Broad Communications Compatibility - Supports HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP - Supports automatic and manual assignment of IP address Easy 0U Installation in EIA-Standard 19 in. Racks - Mounts vertically using included toolless buttons or rack-mounting brackets - Included PDUMVROTATEBRKT allows mounting with rear-facing outlets TAA-Compliant - Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
The PDU3EVSR6H50 14.5kW 3-Phase Switched Power Distribution Unit provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for any IT or industrial application, it features 30 switched outlets (24 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A six-foot cord with Hubbell CS8365C plug connects the PDU to a compatible AC power source, generator or protected UPS. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. A color touchscreen LCD lets you toggle between menus to monitor input current level per phase, output current per load bank and per outlet with ±1% billing-grade accuracy, environmental sensor data and network information. It also generates a unique QR code to allow access to the switchable PDU through a mobile device. The 0U PDU mounts vertically in racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.
Distributes, Monitors and Manages Network-Grade AC Power - 14.5kW 200/208/240V switched PDU with 3-phase input - Recommended for network applications requiring individual outlet control, load shedding and remote monitoring of critical network components - Hubbell CS8365C plug with 6 ft. cord connects to compatible AC power source - Firmware upgrades support future product enhancements 30 Switched Outlets Distribute AC Power - 24 C13 and 6 C19 outlets split into 3 separately breakered load banks - Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices - Plug-lock insert sleeves prevent cables from becoming accidentally disconnected Color Touchscreen LCD - Reports network data, including IP address, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy - Generates unique QR code for read-only access to PowerAlert® Device Manager via mobile device - Full access available by logging into PowerAlert Device Manager via browser as user with read/write credentials Built-In LX Platform Interface - Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH - Supports 10/100 Mbps auto-sensing for communication with an Ethernet network - Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities - No Java required Broad Communications Compatibility - Supports HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP - Supports automatic and manual assignment of IP address Easy 0U Installation in EIA-Standard 19 in. Racks - Mounts vertically using included toolless buttons or rack-mounting brackets - Included PDUMVROTATEBRKT allows mounting with rear-facing outlets TAA-Compliant - Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Products specifications
Attribute nameAttribute value
MonitoringCurrent, Humidity, Power, Temperature
Depth5.16 lbs
Master AC outlets quantity24
Slave AC outlets quantity6
Width2.17"
Height70"
Weight20 lbs
MountingVertical
TypeThree-phase
Country of OriginTaiwan
Housing MaterialMetal
DisplayLCD
Cable Length72"
Design
CertificationTested to UL60950-1: 2007 R10.14 (USA), CAN/CSA-C22.2 NO. 60650-1-07+A1: 2011+A2: 2014 (Canada) Class A Part 15 (Emissions) NOM (Mexico) TAA Compliant
PDU typesSwitched
Technical details
Product colorBlack
Sustainability certificatesRoHS
Features
Rack capacity0U
LED indicatorsY
On/off switchY
Weight & dimensions
Dimensions (WxDxH)2.17 x 2.87 x 70"
Packaging data
Package depthUSB 3.2 Gen 1 (3.1 Gen 1) Type-A, USB 3.2 Gen 1 (3.1 Gen 1) Type-C
Package height11.8 oz
Package width9.65"
Package weight27.1 lbs
Logistics data
Quantity per master (outer) case1 pc(s)
Packaging content
ManualY
Other features
Package dimensions (WxDxH)6.89 x 9.65 x 75.9"
Nominal output voltage200-240 V
Ports & interfaces
Power plug48212 cm³
AC outlets quantity30 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power
Maximum power14500 W
Maximum current35 A
Nominal input voltage200-240 V
Power protection featuresShort circuit
AC input frequency50 - 60 Hz
Operational conditions
Operating temperature (T-T)32 - 122 °F
Storage temperature (T-T)-15 - 60 °C
Operating relative humidity (H-H)5 - 95 %
Operating altitude0 - 118110.2"
Management features
Outlet controlY
Protocols
Supported network protocolsHTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP
*
*
*
Products specifications
Attribute nameAttribute value
MonitoringCurrent, Humidity, Power, Temperature
Depth5.16 lbs
Master AC outlets quantity24
Slave AC outlets quantity6
Width2.17"
Height70"
Weight20 lbs
MountingVertical
TypeThree-phase
Country of OriginTaiwan
Housing MaterialMetal
DisplayLCD
Cable Length72"
Design
CertificationTested to UL60950-1: 2007 R10.14 (USA), CAN/CSA-C22.2 NO. 60650-1-07+A1: 2011+A2: 2014 (Canada) Class A Part 15 (Emissions) NOM (Mexico) TAA Compliant
PDU typesSwitched
Technical details
Product colorBlack
Sustainability certificatesRoHS
Features
Rack capacity0U
LED indicatorsY
On/off switchY
Weight & dimensions
Dimensions (WxDxH)2.17 x 2.87 x 70"
Packaging data
Package depthUSB 3.2 Gen 1 (3.1 Gen 1) Type-A, USB 3.2 Gen 1 (3.1 Gen 1) Type-C
Package height11.8 oz
Package width9.65"
Package weight27.1 lbs
Logistics data
Quantity per master (outer) case1 pc(s)
Packaging content
ManualY
Other features
Package dimensions (WxDxH)6.89 x 9.65 x 75.9"
Nominal output voltage200-240 V
Ports & interfaces
Power plug48212 cm³
AC outlets quantity30 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power
Maximum power14500 W
Maximum current35 A
Nominal input voltage200-240 V
Power protection featuresShort circuit
AC input frequency50 - 60 Hz
Operational conditions
Operating temperature (T-T)32 - 122 °F
Storage temperature (T-T)-15 - 60 °C
Operating relative humidity (H-H)5 - 95 %
Operating altitude0 - 118110.2"
Management features
Outlet controlY
Protocols
Supported network protocolsHTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP
Product tags
  • (54197)