Tripp Lite PDUMH15HVAT power distribution unit (PDU) 10 AC outlet(s) 1U Black
Tripp Lite PDUMH15HVAT. PDU types: Metered, Switched, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 10 AC outlet(s), AC outlet types: C14 coupler, Power plug: IEC 320. LED indicators: Status, Cable length: 144.1" (3.66 m), Certification: TAA. Nominal input voltage: 200-240 V, Maximum current: 10 A, AC input frequency: 50 - 60 Hz. Width: 17.3" (439.9 mm), Depth: 14.4" (367 mm), Dimensions (WxDxH): 17.3 x 14.4 x 1.71" (440 x 367 x 43.4 mm)
SKU: 4711518
Manufacturer part number: PDUMH15HVAT
UPC: 0037332197900
MSRP: $694.52
$512.12
The PDUMH15HVAT 2–2.4kW Single-Phase 200–240V Local Metered Automatic Transfer Switch / ATS PDU enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features 10 C13 outlets. Dual 3.6-meter input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources in a nominal voltage range from 200–240V. Plug lock inserts prevent cords from accidental disconnection. The PDUMH15HVAT constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 2–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Built-in slot supports the optional WEBCARDLX (sold separate), which turn the PDUMH15HVAT into a switched PDU by allowing remote access to the PDU for power monitoring, configuration, outlet control and notifications via web browser, SSH, telnet or SNMP. Digital ammeter monitors total output current. LEDs display outlet on/off status and input power status on primary and secondary inputs.
Primary and Secondary Inputs for Power Redundancy Enables redundant power for network devices with non-redundant power supply configurations Dual 3.6 m input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources 10 C13 outlets
Automatic Transfer Switching Dynamic solid-state (TRIAC) automatic transfer switching Switches to secondary power source if primary source fails or becomes unstable 2–5 ms transfer time ensures uninterrupted operation of connected equipment Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source
Digital Load Meter Easy-to-read ammeter displays total current used by connected equipment
LED Indicators Individual LEDs display outlet on/off status and input power status on primary and secondary inputs
Advanced Network Monitoring Options Built-in card slot accommodates SNMPWEBCARD and WEBCARDLX accessories (sold separately) Optional cards create a switched PDU by allowing remote access for power monitoring, configuration, outlet control and notification via web browser, SSH, telnet or SNMP
Mounts Horizontally in 1U of Rack Space Compatible with EIA-standard 19 in. racks
TAA-Compliant Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
- Single-phase IEC-320 C14 input and 200–240V output
- 10 C13 outlets
- Automatic transfer switching within 5 ms
- Mounts in 1U of space in EIA-standard 19 in. racks
- Digital load meter for real-time output current monitoring