Tripp Lite PDUMH20HVATS power distribution unit (PDU) 10 AC outlet(s) 1U Black

Tripp Lite PDUMH20HVATS. PDU types: Metered, Switched, Rack capacity: 1U, Type: Single-phase. AC outlets quantity: 10 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: C20 coupler. Cable length: 144.1" (3.66 m). Nominal input voltage: 208 - 240 V, Maximum current: 20 A, AC input frequency: 50/60 Hz. Width: 17.3" (440.2 mm), Depth: 14.8" (375.2 mm), Height: 1.72" (43.7 mm)
Manufacturer: Tripp Lite
SKU: 6353202
Manufacturer part number: PDUMH20HVATS
UPC: 0037332261380
MSRP: $638.36
$461.93
Single-Phase 20A ATS PDU Distributes and Monitors Network-Grade Power in Real Time This local metered PDU provides real-time local reporting of the total load level via its built-in digital current meter. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH20HVATS features eight C13 and two C19 200–240V outlets for connecting equipment. Outlets are factory-programmed for sequential turn-on at 250-millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction at startup. Switches from Primary to Secondary Power Source in Milliseconds Dual 12-foot (3.7-meter) power cables with C20 inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources. Dynamic solid-state automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2–5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source. Digital Load Meter Helps Prevent Potentially Expensive Overloads A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low. Mounts into 1U of Rack Space Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. TAA-Compliant for GSA Schedule Purchases The PDUMH20HVATS is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

 

  • 8 C13 and 2 C19 200–240V outlets distribute AC power to connected equipment
  • Switches from primary to secondary power source in <5 ms for constant operation
  • Digital ammeter for on-site real-time load monitoring helps prevent power overloads
  • Dual 12 ft. power cables connect to separate primary and secondary power sources
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Single-Phase 20A ATS PDU Distributes and Monitors Network-Grade Power in Real Time This local metered PDU provides real-time local reporting of the total load level via its built-in digital current meter. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH20HVATS features eight C13 and two C19 200–240V outlets for connecting equipment. Outlets are factory-programmed for sequential turn-on at 250-millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction at startup. Switches from Primary to Secondary Power Source in Milliseconds Dual 12-foot (3.7-meter) power cables with C20 inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources. Dynamic solid-state automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2–5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source. Digital Load Meter Helps Prevent Potentially Expensive Overloads A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low. Mounts into 1U of Rack Space Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. TAA-Compliant for GSA Schedule Purchases The PDUMH20HVATS is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

 

  • 8 C13 and 2 C19 200–240V outlets distribute AC power to connected equipment
  • Switches from primary to secondary power source in <5 ms for constant operation
  • Digital ammeter for on-site real-time load monitoring helps prevent power overloads
  • Dual 12 ft. power cables connect to separate primary and secondary power sources
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Products specifications
Attribute name Attribute value
Master (outer) case width 20.8"
Master (outer) case height 8517.62.0090
Country of Origin Blue
Depth 14.8"
Weight 10.3 lbs
Mounting Horizontal
Display LED
Cable Length 144.1"
Type Single-phase
Rack mount kit Y
Master (outer) case length 23.2"
Width 17.3"
Height 1.72"
Housing Material Metal
Master (outer) case weight 17.8 lbs
Design
PDU types Metered, Switched
Technical details
Product color Black
Sustainability certificates RoHS
Sustainability compliance Y
Features
Rack capacity 1U
LED indicators Y
Packaging data
Package depth 23.2"
Package height 5.3"
Package weight 16.6 lbs
Package width 20.8"
Logistics data
Quantity per master (outer) case 1 pc(s)
Packaging content
Manual Y
Cables included AC
Other features
Nominal output voltage 200 - 240 V
Ports & interfaces
AC outlets quantity 10 AC outlet(s)
AC outlet types C13 coupler, C19 coupler
Power plug C20 coupler
Serial ports quantity 1
Power
Nominal input voltage 208 - 240 V
Maximum power 3840 W
Maximum current 20 A
AC input frequency 50/60 Hz
Operational conditions
Storage temperature (T-T) 120 V
Operating relative humidity (H-H) 5 - 95 %
*
*
*
Products specifications
Attribute name Attribute value
Master (outer) case width 20.8"
Master (outer) case height 8517.62.0090
Country of Origin Blue
Depth 14.8"
Weight 10.3 lbs
Mounting Horizontal
Display LED
Cable Length 144.1"
Type Single-phase
Rack mount kit Y
Master (outer) case length 23.2"
Width 17.3"
Height 1.72"
Housing Material Metal
Master (outer) case weight 17.8 lbs
Design
PDU types Metered, Switched
Technical details
Product color Black
Sustainability certificates RoHS
Sustainability compliance Y
Features
Rack capacity 1U
LED indicators Y
Packaging data
Package depth 23.2"
Package height 5.3"
Package weight 16.6 lbs
Package width 20.8"
Logistics data
Quantity per master (outer) case 1 pc(s)
Packaging content
Manual Y
Cables included AC
Other features
Nominal output voltage 200 - 240 V
Ports & interfaces
AC outlets quantity 10 AC outlet(s)
AC outlet types C13 coupler, C19 coupler
Power plug C20 coupler
Serial ports quantity 1
Power
Nominal input voltage 208 - 240 V
Maximum power 3840 W
Maximum current 20 A
AC input frequency 50/60 Hz
Operational conditions
Storage temperature (T-T) 120 V
Operating relative humidity (H-H) 5 - 95 %
Product tags
  • (56515)