Tripp Lite PDUMH32HVAT power distribution unit (PDU) 18 AC outlet(s) 2U Black
Tripp Lite PDUMH32HVAT. PDU types: Metered, Switched, Rack capacity: 2U, Type: Single-phase. AC outlets quantity: 18 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC309. Cable length: 118.1" (3 m). Nominal input voltage: 200-240 V, Maximum current: 32 A, AC input frequency: 50 - 60 Hz. Width: 17.5" (444.5 mm), Depth: 12.5" (317.5 mm), Dimensions (WxDxH): 17.5 x 12.5 x 3.46" (444 x 317 x 88 mm)
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: 4508024
Manufacturer part number: PDUMH32HVAT
UPC: 0037332186881
MSRP: $1,581.84
$1,144.64
The PDUMH32HVAT 7.7kW Single-Phase 200-240V Local Metered Automatic Transfer Switch / ATS PDU provides power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 2U of space in EIA-standard 19-inch racks and features 18 outlets (16 C13 and two C19) in two load banks, each bank protected by a 20A circuit breaker. Dual three-meter input cords with IEC 309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase 200-240V power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Multifunction digital display with LED indicators reports output current, voltage and kW loading information.
Primary and Secondary Inputs for Power Redundancy Provides power monitoring and enables redundant power for network devices with non-redundant power supply configurations Dual 3m input cords with IEC 309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase power sources
Automatic Transfer Switching Dynamic solid-state (TRIAC) automatic transfer switching Switches to secondary power source if primary source fails or becomes unstable 1–5 ms transfer time ensures uninterrupted operation of connected equipment Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source
Multifunction Digital Display Front-panel digital display with LED indicators reports output current, voltage and kW loading information
20A Circuit Breakers Protect each of 2 single-phase output banks Front-panel LED indicates when breaker has tripped Cord Retention Sleeves Set of Plug-lock output power cable retention sleeves prevent accidental disconnection of connected devices
Mounts Horizontally in 2U of Rack Space Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
TAA-Compliant Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
- Single-phase IEC 309 32A Blue (2P+E) input and 200-240V output
- 16 C13 and 2 C19 outlets in 2 load banks
- Automatic transfer switching within 1–5 ms
- Mounts in 2U of space in EIA-standard 19 in. racks
- Multifunction digital display with LED indicators