Tripp Lite's SMART3000NET intelligent, line interactive large tower UPS system protects servers, networking accessories and telecommunications equipment from blackouts, voltage fluctuations and transient surges. Large internal batteries offer 23 minutes half load runtime and 7 minutes fully loaded. Runtime is expandable with optional BP24V28-2U (limit 1) and BP24V70-3U (multi-pack compatible) external battery packs. 3000VA/2400 watt power handling capability supports a variety of networking, telecom and other sensitive electronic applications. Includes 8 protected outlets. Supports remote monitoring of UPS and site power conditions via built-in RS-232 enabled monitoring port, plus standard UPS monitoring via 2 built in contact closure ports. Includes PowerAlert UPS monitoring and unattended shutdown software with complete cabling. Built-in audible alarm and front panel LEDs indicate line power, battery power, battery charge level, load level and voltage regulation status. Network grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges. - SMART 3000NET line interactive UPS offers battery derived AC output during power outages, voltage regulation during brownouts and overvoltages, plus network-grade AC surge suppression - 3000VA/2400 watt power handling capability supports a variety of networking, telecom and other sensitive electronic devices - Large internal batteries offer runtimes of 23 minutes at half load (1500VA/1200 watts) and 7 minutes at full load (3000VA/2400 watts) - Runtime is further expandable with optional external BP24V28-2U (limit 1) and BP24V70-3U (multi-pack compatible) battery packs - Automatic Voltage Regulation (AVR) circuits maintain 120V nominal output over an input voltage range of 87-140V - Includes 8 fully protected outlets (4 NEMA 5-15R & 4 NEMA 5-15/20R) with 2 single outlet load banks that can be individually powered off and back on again via software interface - PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging, email notification, event logging and running user defined script commands - Offers simultaneous monitoring of up to 3 directly connected devices through included DB9 contact closure and RS-232 enabled interfaces, or the monitoring of any number of additional servers over IP with included PowerAlert monitoring software - In addition to the contact closure monitoring of on battery, low battery and power restored messaging, built-in RS-232 interface supports messaging of UPS and line power status, including AC line voltage, DC battery voltage and remaining battery capacity - Supports activate self-test and UPS output power control for delayed or immediate reboot of connected equipment - Diagnostic LEDs (indicate 17 performance conditions)
Products specifications
Attribute name | Attribute value |
---|
Weight | 89.1 lbs |
Battery Type | BP24V28-2U, BP24V70-3U |
Output voltage regulation | -13 / +5 % |
Battery Recharge Time | 9 h |
Housing Material | Polyvinyl chloride (PVC) |
Cable Length | 94.5" |
Power factor | 0.8 |
Width | 9.02" |
Depth | 12.5" |
Height | 17" |
Automatic Voltage Regulation (AVR) | Y |
Input Frequency | 60 Hz |
UPS topology | Line-Interactive |
Number of input phases | 1 |
EMI/RFI noise filtering | Y |
Cold start | Y |
Certification | FCC, CSA, NOM, UL1778 |
Form factor | Tower |
Product color | Black |
Sustainability certificates | RoHS |
Input operation voltage (min) | 87 V |
Input operation voltage (max) | 140 V |
Output power | 2400 W |
Output operation voltage (min) | 120 V |
Efficiency | 99 % |
Cooling type | Active |
LED indicators | Y |
Audible alarm(s) | Y |
Surge energy rating | 480 J |
Waveform | Sine |
Package depth | Lenovo |
Package width | 12.8" |
Package weight | 96.1 lbs |
Package height | 22.2" |
AC outlet types | NEMA 5–15R, NEMA 5–20R |
Serial ports quantity | 3 |
AC outlets quantity | 8 AC outlet(s) |
RS-232 ports | 1 |
Power plug | NEMA L5-30P |
Maximum current | 22 A |
Power protection features | Over power, Under voltage |
Output power capacity | 3 kVA |
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -15 - 50 °C |
Operating relative humidity (H-H) | 0 - 95 % |
Typical backup time at half load | 23 min |
Typical backup time at full load | 7 min |