Tripp Lite SMART2200VS uninterruptible power supply (UPS) Line-Interactive 2.2 kVA 1600 W 9 AC outlet(s)

Tripp Lite SMART2200VS. UPS topology: Line-Interactive, Output power capacity: 2.2 kVA, Output power: 1600 W. AC outlet types: NEMA 5–15R, NEMA 5–20R, Power plug: NEMA 5-20P, AC outlets quantity: 9 AC outlet(s). Typical backup time at full load: 7 min, Typical backup time at half load: 19 min, Battery recharge time: 4 h. Form factor: Tower, Product color: White, Housing material: Polycarbonate (PC). Width: 9.25" (235 mm), Depth: 12" (304.8 mm), Height: 14.3" (362 mm)
Manufacturer: Tripp Lite
Availability: In stock
SKU: 990369
Manufacturer part number: SMART2200VS
UPC: 0037332115874
MSRP: $1,606.18
$1,162.26
Tripp Lite's SMART 2200VS intelligent, line interactive UPS protects server, networking and telecommunications equipment from blackouts, voltage fluctuations and transient surges. Small footprint, tower UPS system occupies only 106 square inches of floor space with a height of only 14.25 inches. Large capacity 2200 VA/ 1600 watt rated UPS system offers 7 minutes runtime at full load and 19 minutes at half load during power failures. Line interactive voltage regulation corrects brownouts as low as 79V and overvoltages as high as 147V to fully regulated 120V nominal output for smooth continuous operation of connected equipment. Includes a total of 9 outlets, 3 pairs of which can be individually powered off and back on via software interface to selectively reboot remote equipment or shed less critical loads to extend battery runtime for more critical loads. Includes slot for internal SNMPWEBCARD, plus 2 DB9 and 2 USB enhanced monitoring ports for unattended shutdown, remote control and monitoring of UPS system and power data. Ships in attractive gray color scheme. Compatible with Tripp Lite's PowerAlert and Watchdog service software. - 2200VA/1600 watt output capacity accommodates a variety of server, networking and telecom devices - High power density 2.2kVA UPS system occupies only 106 square inches of floor space with a height of only 14.25 inches - Compatible with North American 120V/60 Hz power as found in the USA, Canada and Mexico - Offers 7 minutes runtime with a full load of 2200VA and 19 minutes with a half load of 1100VA - Line interactive voltage regulation corrects severe brownouts and overvoltages from 79 to 147v back to normal 120v levels without using battery power - 9 total outlets (7 NEMA5-15R; 2 NEMA5-15/20R) - Includes NEMA 5-20 straight blade 20 amp input plug connection - Notification of system status via 5 LEDs and multi-function audible alarms - Included PowerAlert Software provides e-mail notification of power problems and the simultaneous automatic unattended shutdown of multiple servers - 4 built-in communications ports (2-DB9, 2-USB) for remote monitoring and unattended shutdown - Slot for SNMP/web card (part#: SNMPWEBCARD) and environmental sensor (part#: ENVIROSENSE) for remote communications in large IP environments - Supports Tripp Lite's WatchDog software application to restore unresponsive programs by automatically restarting them and rebooting completely locked computers by automatically switching UPS power off and back on again - Communication ports support on battery, low battery, power restored, AC line voltage, DC battery voltage, load percentage, battery charge current, battery capacity, internal UPS temperature and line frequency status messaging. Interface supports timed inverter shutoff after unattended shutdown, activate self-test and 10 second reboot of connected equipment - 3 pairs of customized load management receptacles can be individually powered off and back on again via software interface to reboot remote equipment or shed less critical loads to extend battery runtime for the most critical equipment - Built-in Emergency Power Off (EPO) interface supports emergency shutoff in large facilities - Hot-swappable/user replaceable batteries allow on-site battery replacement without powering off connected equipment - UPS battery set ships fully assembled and ready for use, no time consuming, connection of individual internal batteries by user is necessary - UL (USA), cUL (Canada), NOM (Mexico), Class A (Emissions)
Tripp Lite's SMART 2200VS intelligent, line interactive UPS protects server, networking and telecommunications equipment from blackouts, voltage fluctuations and transient surges. Small footprint, tower UPS system occupies only 106 square inches of floor space with a height of only 14.25 inches. Large capacity 2200 VA/ 1600 watt rated UPS system offers 7 minutes runtime at full load and 19 minutes at half load during power failures. Line interactive voltage regulation corrects brownouts as low as 79V and overvoltages as high as 147V to fully regulated 120V nominal output for smooth continuous operation of connected equipment. Includes a total of 9 outlets, 3 pairs of which can be individually powered off and back on via software interface to selectively reboot remote equipment or shed less critical loads to extend battery runtime for more critical loads. Includes slot for internal SNMPWEBCARD, plus 2 DB9 and 2 USB enhanced monitoring ports for unattended shutdown, remote control and monitoring of UPS system and power data. Ships in attractive gray color scheme. Compatible with Tripp Lite's PowerAlert and Watchdog service software. - 2200VA/1600 watt output capacity accommodates a variety of server, networking and telecom devices - High power density 2.2kVA UPS system occupies only 106 square inches of floor space with a height of only 14.25 inches - Compatible with North American 120V/60 Hz power as found in the USA, Canada and Mexico - Offers 7 minutes runtime with a full load of 2200VA and 19 minutes with a half load of 1100VA - Line interactive voltage regulation corrects severe brownouts and overvoltages from 79 to 147v back to normal 120v levels without using battery power - 9 total outlets (7 NEMA5-15R; 2 NEMA5-15/20R) - Includes NEMA 5-20 straight blade 20 amp input plug connection - Notification of system status via 5 LEDs and multi-function audible alarms - Included PowerAlert Software provides e-mail notification of power problems and the simultaneous automatic unattended shutdown of multiple servers - 4 built-in communications ports (2-DB9, 2-USB) for remote monitoring and unattended shutdown - Slot for SNMP/web card (part#: SNMPWEBCARD) and environmental sensor (part#: ENVIROSENSE) for remote communications in large IP environments - Supports Tripp Lite's WatchDog software application to restore unresponsive programs by automatically restarting them and rebooting completely locked computers by automatically switching UPS power off and back on again - Communication ports support on battery, low battery, power restored, AC line voltage, DC battery voltage, load percentage, battery charge current, battery capacity, internal UPS temperature and line frequency status messaging. Interface supports timed inverter shutoff after unattended shutdown, activate self-test and 10 second reboot of connected equipment - 3 pairs of customized load management receptacles can be individually powered off and back on again via software interface to reboot remote equipment or shed less critical loads to extend battery runtime for the most critical equipment - Built-in Emergency Power Off (EPO) interface supports emergency shutoff in large facilities - Hot-swappable/user replaceable batteries allow on-site battery replacement without powering off connected equipment - UPS battery set ships fully assembled and ready for use, no time consuming, connection of individual internal batteries by user is necessary - UL (USA), cUL (Canada), NOM (Mexico), Class A (Emissions)
Products specifications
Attribute nameAttribute value
Master (outer) case weight58 lbs
Master (outer) case length5.12"
Output voltage regulation-18, +8 %
Weight52.5 lbs
Cable Length96.1"
Power factor0.7
Country of OriginChina
Width9.25"
Depth12"
Height14.3"
Housing MaterialPolycarbonate (PC)
Automatic Voltage Regulation (AVR)Y
Battery Recharge Time4 h
Emergency Power Off (EPO)Y
Input Frequency60 Hz
Non-operating relative humidity (non-condensing)0 - 95 %
UPS topologyLine-Interactive
Master (outer) case width16.5"
Master (outer) case height19.3"
Number of input phases1
EMI/RFI noise filteringY
Cold startY
Design
CertificationUL1778, CSA, NOM, FCC
Form factorTower
Technical details
Product colorWhite
Sustainability certificatesRoHS
Features
Input operation voltage (min)79 V
Input operation voltage (max)60 Hz
Cooling typeActive
LED indicatorsY
Output power1600 W
Noise level47 dB
Audible alarm(s)Y
Surge energy rating480 J
Efficiency94 %
WaveformSine
Packaging data
Package width16.5"
Package depth14.2"
Package height19.3"
Package weight58 lbs
Logistics data
Quantity per master (outer) case1 pc(s)
Ports & interfaces
AC outlet typesNEMA 5–15R, NEMA 5–20R
Modem (RJ-11) ports3:1
AC outlets quantity9 AC outlet(s)
RS-232 ports1
USB 2.0 ports quantity2
Power plugNEMA 5-20P
Serial ports quantity2
Power
Maximum current20 A
Output power capacity2.2 kVA
Power protection featuresOver voltage, Under voltage
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Battery
Typical backup time at full load7 min
Typical backup time at half load19 min
Hot-swap batteryY
*
*
*
Products specifications
Attribute nameAttribute value
Master (outer) case weight58 lbs
Master (outer) case length5.12"
Output voltage regulation-18, +8 %
Weight52.5 lbs
Cable Length96.1"
Power factor0.7
Country of OriginChina
Width9.25"
Depth12"
Height14.3"
Housing MaterialPolycarbonate (PC)
Automatic Voltage Regulation (AVR)Y
Battery Recharge Time4 h
Emergency Power Off (EPO)Y
Input Frequency60 Hz
Non-operating relative humidity (non-condensing)0 - 95 %
UPS topologyLine-Interactive
Master (outer) case width16.5"
Master (outer) case height19.3"
Number of input phases1
EMI/RFI noise filteringY
Cold startY
Design
CertificationUL1778, CSA, NOM, FCC
Form factorTower
Technical details
Product colorWhite
Sustainability certificatesRoHS
Features
Input operation voltage (min)79 V
Input operation voltage (max)60 Hz
Cooling typeActive
LED indicatorsY
Output power1600 W
Noise level47 dB
Audible alarm(s)Y
Surge energy rating480 J
Efficiency94 %
WaveformSine
Packaging data
Package width16.5"
Package depth14.2"
Package height19.3"
Package weight58 lbs
Logistics data
Quantity per master (outer) case1 pc(s)
Ports & interfaces
AC outlet typesNEMA 5–15R, NEMA 5–20R
Modem (RJ-11) ports3:1
AC outlets quantity9 AC outlet(s)
RS-232 ports1
USB 2.0 ports quantity2
Power plugNEMA 5-20P
Serial ports quantity2
Power
Maximum current20 A
Output power capacity2.2 kVA
Power protection featuresOver voltage, Under voltage
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Battery
Typical backup time at full load7 min
Typical backup time at half load19 min
Hot-swap batteryY