Tripp Lite SMART2500XLHG. UPS topology: Line-Interactive, Output power capacity: 2.2 kVA, Output power: 1920 W. AC outlet types: C13 coupler, NEMA 5–15, Power plug: C20 coupler, AC outlets quantity: 8 AC outlet(s). Typical backup time at full load: 4.4 min, Typical backup time at half load: 13 min, Battery recharge time: 4.5 h. Form factor: Tower, Product color: White, Housing material: Polyvinyl chloride (PVC). Width: 8.9" (226.1 mm), Depth: 19.1" (484.9 mm), Height: 9.72" (246.9 mm)
Manufacturer: Tripp Lite
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: 3475435
Manufacturer part number: SMART2500XLHG
UPC: 0037332168283
MSRP: $3,465.28
$2,507.52
UL 60601-1 compliance is required for UPS systems within patient care areas. Get complete, compliant power protection with Tripp Lite’s SMART2500XLHG SmartPro® Medical UPS System. The SMART2500XLHG provides a high load capacity 2200VA/1920W, full UL 60601-1 3rd edition compliance. Protects connected medical equipment against data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges. It features a USB port, input locking clamp, equipotential earth bonding lug, 4 NEMA 5-15/20R outlets, and 4 IEC C13 outlets for universally adaptable outlet options. The SMART2500XLHG offers a complete power protection solution for clinical labs, diagnostic imaging, ophthalmology, medical equipment, imaging and other devices requiring medical grade protection. With built-in Faraday shielding, the SMART2500XLHG provides full line isolation and reduces the cumulative leakage current of connected equipment to less than 100 μA for optimal safety in patient care areas. Full isolation also provides continuous noise filtering and enhanced common mode surge suppression. Featuring advanced line-interactive operation, it provides regulated 120V nominal output without using battery power during brownouts and overvoltages. Large internal batteries support connected equipment during blackouts and optional external battery packs (BP48V24-2U and BP48V60RT-3U) provide extended runtime tailored to your application. The SMART2500XLHG features a USB communication port that works with included PowerAlert software to provide UPS and site power monitoring plus automatic file saves and safe unattended shutdown of connected equipment in the event of a prolonged power failure. - Ideal UPS protection for applications in patient-care areas where UL 60601-1 3rd edition listed medical electrical equipment is required - Built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes - Full line isolation prevents shock potential and operational problems in sensitive electronic equipment - Provides connected equipment with continuous power during short and long duration loss of commercial power - Expandable runtime is available with the addition of one or more external battery packs (BP48V24-2U and BP24V60RT-3U) - Line-interactive voltage regulation corrects brownouts and over voltages from 83 to 143V back to usable 120V output levels, without using battery power - Resistant to electrostatic discharge - Supports loads up to 2200VA/1920W - 13 min half-load runtime (1100VA/960W), 4 min full load runtime (2200VA/1920W) - Input: IEC320-C20 inlet with locking clamp/ Output: 4 NEMA 5-15/20R and 4 IEC C13 - Built-in USB, DB9 (RS-232) & optional SNMPWEBCARD accessory monitoring options - PowerAlert unattended shutdown software and complete cabling included - Complete surge protection (510 Joules), line isolation and EMI/RFI noise filtering - 5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload & battery low/replace - Battery replacement door and back panel grounding lug - Relay IO card allows users to communicate UPS status & events via 6 configurable contact closure outputs
UL 60601-1 compliance is required for UPS systems within patient care areas. Get complete, compliant power protection with Tripp Lite’s SMART2500XLHG SmartPro® Medical UPS System. The SMART2500XLHG provides a high load capacity 2200VA/1920W, full UL 60601-1 3rd edition compliance. Protects connected medical equipment against data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges. It features a USB port, input locking clamp, equipotential earth bonding lug, 4 NEMA 5-15/20R outlets, and 4 IEC C13 outlets for universally adaptable outlet options. The SMART2500XLHG offers a complete power protection solution for clinical labs, diagnostic imaging, ophthalmology, medical equipment, imaging and other devices requiring medical grade protection. With built-in Faraday shielding, the SMART2500XLHG provides full line isolation and reduces the cumulative leakage current of connected equipment to less than 100 μA for optimal safety in patient care areas. Full isolation also provides continuous noise filtering and enhanced common mode surge suppression. Featuring advanced line-interactive operation, it provides regulated 120V nominal output without using battery power during brownouts and overvoltages. Large internal batteries support connected equipment during blackouts and optional external battery packs (BP48V24-2U and BP48V60RT-3U) provide extended runtime tailored to your application. The SMART2500XLHG features a USB communication port that works with included PowerAlert software to provide UPS and site power monitoring plus automatic file saves and safe unattended shutdown of connected equipment in the event of a prolonged power failure. - Ideal UPS protection for applications in patient-care areas where UL 60601-1 3rd edition listed medical electrical equipment is required - Built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes - Full line isolation prevents shock potential and operational problems in sensitive electronic equipment - Provides connected equipment with continuous power during short and long duration loss of commercial power - Expandable runtime is available with the addition of one or more external battery packs (BP48V24-2U and BP24V60RT-3U) - Line-interactive voltage regulation corrects brownouts and over voltages from 83 to 143V back to usable 120V output levels, without using battery power - Resistant to electrostatic discharge - Supports loads up to 2200VA/1920W - 13 min half-load runtime (1100VA/960W), 4 min full load runtime (2200VA/1920W) - Input: IEC320-C20 inlet with locking clamp/ Output: 4 NEMA 5-15/20R and 4 IEC C13 - Built-in USB, DB9 (RS-232) & optional SNMPWEBCARD accessory monitoring options - PowerAlert unattended shutdown software and complete cabling included - Complete surge protection (510 Joules), line isolation and EMI/RFI noise filtering - 5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload & battery low/replace - Battery replacement door and back panel grounding lug - Relay IO card allows users to communicate UPS status & events via 6 configurable contact closure outputs
Products specifications
Attribute nameAttribute value
Power factor0.87
Master (outer) case weight100.1 lbs
HeightDesk
Weight73.2 lbs
Master (outer) case height16"
Width8.9"
Depth19.1"
Housing MaterialPolyvinyl chloride (PVC)
Country of OriginChina
Response Time4 ms
Battery Recharge Time4.5 h
Emergency Power Off (EPO)Y
Input Frequency60 Hz
Cable Length70.9"
UPS topologyLine-Interactive
Master (outer) case length24"
Master (outer) case width14"
EMI/RFI noise filteringY
Cold startY
Design
CertificationUL, CSA, FCC, EMI
Form factorTower
Technical details
Product colorWhite
Sustainability certificatesRoHS
Features
Output operation voltage (min)94 %
Built-in fanY
Surge energy rating510 J
Input operation voltage (max)120 V
Audible alarm modesBattery replacement
Cooling typeActive
LED indicatorsY
Output power1920 W
Audible alarm(s)Y
Input operation voltage (min)120 V
Output operation voltage (max)120 V
Surge protectionY
Packaging data
Package width14"
Package height16"
Package weight100.1 lbs
Package depth24"
Logistics data
Quantity per master (outer) case1 pc(s)
Ports & interfaces
AC outlet typesC13 coupler, NEMA 5–15
AC outlets quantity8 AC outlet(s)
USB 2.0 ports quantity1
Power plugC20 coupler
Serial ports quantity1
Power
Maximum current15 A
Output power capacity2.2 kVA
Power protection featuresOver voltage, Under voltage
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Battery
Typical backup time at half load220 J
Typical backup time at full load4.4 min
Hot-swap batteryY
Number of battery cells1
*
*
*
Products specifications
Attribute nameAttribute value
Power factor0.87
Master (outer) case weight100.1 lbs
HeightDesk
Weight73.2 lbs
Master (outer) case height16"
Width8.9"
Depth19.1"
Housing MaterialPolyvinyl chloride (PVC)
Country of OriginChina
Response Time4 ms
Battery Recharge Time4.5 h
Emergency Power Off (EPO)Y
Input Frequency60 Hz
Cable Length70.9"
UPS topologyLine-Interactive
Master (outer) case length24"
Master (outer) case width14"
EMI/RFI noise filteringY
Cold startY
Design
CertificationUL, CSA, FCC, EMI
Form factorTower
Technical details
Product colorWhite
Sustainability certificatesRoHS
Features
Output operation voltage (min)94 %
Built-in fanY
Surge energy rating510 J
Input operation voltage (max)120 V
Audible alarm modesBattery replacement
Cooling typeActive
LED indicatorsY
Output power1920 W
Audible alarm(s)Y
Input operation voltage (min)120 V
Output operation voltage (max)120 V
Surge protectionY
Packaging data
Package width14"
Package height16"
Package weight100.1 lbs
Package depth24"
Logistics data
Quantity per master (outer) case1 pc(s)
Ports & interfaces
AC outlet typesC13 coupler, NEMA 5–15
AC outlets quantity8 AC outlet(s)
USB 2.0 ports quantity1
Power plugC20 coupler
Serial ports quantity1
Power
Maximum current15 A
Output power capacity2.2 kVA
Power protection featuresOver voltage, Under voltage
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Battery
Typical backup time at half load220 J
Typical backup time at full load4.4 min
Hot-swap batteryY
Number of battery cells1