UL 60601-1 compliance is required for UPS systems within patient care areas. Get complete, compliant power protection with Tripp Lite’s SMART2500XLHG SmartPro® Medical UPS System. The SMART2500XLHG provides a high load capacity 2200VA/1920W, full UL 60601-1 3rd edition compliance. Protects connected medical equipment against data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges. It features a USB port, input locking clamp, equipotential earth bonding lug, 4 NEMA 5-15/20R outlets, and 4 IEC C13 outlets for universally adaptable outlet options. The SMART2500XLHG offers a complete power protection solution for clinical labs, diagnostic imaging, ophthalmology, medical equipment, imaging and other devices requiring medical grade protection. With built-in Faraday shielding, the SMART2500XLHG provides full line isolation and reduces the cumulative leakage current of connected equipment to less than 100 μA for optimal safety in patient care areas. Full isolation also provides continuous noise filtering and enhanced common mode surge suppression. Featuring advanced line-interactive operation, it provides regulated 120V nominal output without using battery power during brownouts and overvoltages. Large internal batteries support connected equipment during blackouts and optional external battery packs (BP48V24-2U and BP48V60RT-3U) provide extended runtime tailored to your application. The SMART2500XLHG features a USB communication port that works with included PowerAlert software to provide UPS and site power monitoring plus automatic file saves and safe unattended shutdown of connected equipment in the event of a prolonged power failure. - Ideal UPS protection for applications in patient-care areas where UL 60601-1 3rd edition listed medical electrical equipment is required - Built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes - Full line isolation prevents shock potential and operational problems in sensitive electronic equipment - Provides connected equipment with continuous power during short and long duration loss of commercial power - Expandable runtime is available with the addition of one or more external battery packs (BP48V24-2U and BP24V60RT-3U) - Line-interactive voltage regulation corrects brownouts and over voltages from 83 to 143V back to usable 120V output levels, without using battery power - Resistant to electrostatic discharge - Supports loads up to 2200VA/1920W - 13 min half-load runtime (1100VA/960W), 4 min full load runtime (2200VA/1920W) - Input: IEC320-C20 inlet with locking clamp/ Output: 4 NEMA 5-15/20R and 4 IEC C13 - Built-in USB, DB9 (RS-232) & optional SNMPWEBCARD accessory monitoring options - PowerAlert unattended shutdown software and complete cabling included - Complete surge protection (510 Joules), line isolation and EMI/RFI noise filtering - 5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload & battery low/replace - Battery replacement door and back panel grounding lug - Relay IO card allows users to communicate UPS status & events via 6 configurable contact closure outputs
Products specifications
Attribute name | Attribute value |
---|
Power factor | 0.87 |
Master (outer) case weight | 100.1 lbs |
Height | Desk |
Weight | 73.2 lbs |
Master (outer) case height | 16" |
Width | 8.9" |
Depth | 19.1" |
Housing Material | Polyvinyl chloride (PVC) |
Country of Origin | China |
Response Time | 4 ms |
Battery Recharge Time | 4.5 h |
Emergency Power Off (EPO) | Y |
Input Frequency | 60 Hz |
Cable Length | 70.9" |
UPS topology | Line-Interactive |
Master (outer) case length | 24" |
Master (outer) case width | 14" |
EMI/RFI noise filtering | Y |
Cold start | Y |
Certification | UL, CSA, FCC, EMI |
Form factor | Tower |
Product color | White |
Sustainability certificates | RoHS |
Output operation voltage (min) | 94 % |
Built-in fan | Y |
Surge energy rating | 510 J |
Input operation voltage (max) | 120 V |
Audible alarm modes | Battery replacement |
Cooling type | Active |
LED indicators | Y |
Output power | 1920 W |
Audible alarm(s) | Y |
Input operation voltage (min) | 120 V |
Output operation voltage (max) | 120 V |
Surge protection | Y |
Package width | 14" |
Package height | 16" |
Package weight | 100.1 lbs |
Package depth | 24" |
Quantity per master (outer) case | 1 pc(s) |
AC outlet types | C13 coupler, NEMA 5–15 |
AC outlets quantity | 8 AC outlet(s) |
USB 2.0 ports quantity | 1 |
Power plug | C20 coupler |
Serial ports quantity | 1 |
Maximum current | 15 A |
Output power capacity | 2.2 kVA |
Power protection features | Over voltage, Under voltage |
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -15 - 50 °C |
Operating relative humidity (H-H) | 0 - 95 % |
Typical backup time at half load | 220 J |
Typical backup time at full load | 4.4 min |
Hot-swap battery | Y |
Number of battery cells | 1 |