Tripp Lite SU20KRTAA uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA 18000 W 10 AC outlet(s)

Tripp Lite SU20KRTAA. UPS topology: Double-conversion (Online), Output power capacity: 20 kVA, Output power: 18000 W. AC outlet types: C19 coupler, NEMA L6-30R, Power plug: Hardwire, AC outlets quantity: 10 AC outlet(s). Battery technology: Sealed Lead Acid (VRLA), Typical backup time at full load: 4.3 min, Typical backup time at half load: 12.5 min. Form factor: Rackmount, Product color: Black, Housing material: Steel. Depth: 33" (838.2 mm), Battery weight: 159 lbs (72.1 kg), Package width: 40.3" (1022.4 mm)
Manufacturer: Tripp Lite
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: 5258596
Manufacturer part number: SU20KRTAA
UPC: 0037332223777
MSRP: $19,132.20
$13,844.32
Protects Mission-Critical Rack-Mounted Equipment against Damage, Downtime and Data Loss This N+1 UPS system protects connected equipment against damage, downtime and data loss due to power outages, voltage fluctuations and transient surges. Featuring an 18,000W capacity, high 0.9 power factor, true on-line operation with pure sine wave output and zero transfer time to battery, the SmartOnline® SU20KRTAA provides the highest level of battery backup and AC power protection for critical server, network and telecom equipment. It offers automatic N+1 redundancy at load levels up to 10kVA and non-redundant operation from 10kVA all the way up to 20kVA. Reliable, Expandable Battery Backup UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The external battery provides 12.5 minutes of support at half load and 4.3 minutes at full load. During normal operation, incoming utility power keeps the battery fully charged so backup power will be available when needed. For mission-critical applications demanding continuous uptime, the 20kVA UPS can provide expandable runtime with optional external battery packs, such as Tripp Lite’s field-replaceable, hot-swappable BP240V10RT3UTAA (sold separately). A battery-independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries. Easily Hot-Swappable with No Expensive Service Calls or Downtime Needed With its parallel PDU, the SU20KRTAA with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation. When making repairs or replacing a battery, no lengthy service calls or downtime are necessary. Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring Front-panel LEDs indicate line power, online mode, bypass mode, on-battery, charger and AC output status at a glance. The LCD readout with scroll controls supports visual monitoring of a variety of control options to support advanced UPS settings and configurations. The panel rotates for comfortable viewing in rack-mount or tower configuration. Optional WEBCARDLX Network Interface Offers 24/7 Access An accessory slot accommodates the optional Java-free HTML5-based WEBCARDLX interface, which enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads, power loss and downtime. Advanced Communications Ports USB and DB9 ports (cables are included) enable data-saving unattended shutdown of connected systems when used with Tripp Lite’s free downloadable PowerAlert® software. Capabilities include detailed monitoring of load levels, self-test data and utility power conditions. Versatile Installation Options Hardware is included for mounting the 20kVA UPS system in 12U of space in an EIA-standard 19-inch 4-post rack. Use four optional 2POSTRMKITHD kits for 2-post rack mounting or two optional 2-9USTAND kits for mounting in an upright tower position. TAA-Compliant UPS for GSA Schedule Purchases The SU20KRTAA is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases. 2-Year Warranty, $250K Ultimate Lifetime Insurance and Environmentally Responsible Design The SU20KRTAA comes with a 2-year warranty and $250,000 of Ultimate Lifetime Insurance for any connected components damaged by a power surge (U.S., Canada and Puerto Rico only). It’s manufactured in compliance with strict RoHS specifications, reflecting Tripp Lite’s commitment to environmental responsibility.
Protects Mission-Critical Rack-Mounted Equipment against Damage, Downtime and Data Loss This N+1 UPS system protects connected equipment against damage, downtime and data loss due to power outages, voltage fluctuations and transient surges. Featuring an 18,000W capacity, high 0.9 power factor, true on-line operation with pure sine wave output and zero transfer time to battery, the SmartOnline® SU20KRTAA provides the highest level of battery backup and AC power protection for critical server, network and telecom equipment. It offers automatic N+1 redundancy at load levels up to 10kVA and non-redundant operation from 10kVA all the way up to 20kVA. Reliable, Expandable Battery Backup UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The external battery provides 12.5 minutes of support at half load and 4.3 minutes at full load. During normal operation, incoming utility power keeps the battery fully charged so backup power will be available when needed. For mission-critical applications demanding continuous uptime, the 20kVA UPS can provide expandable runtime with optional external battery packs, such as Tripp Lite’s field-replaceable, hot-swappable BP240V10RT3UTAA (sold separately). A battery-independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries. Easily Hot-Swappable with No Expensive Service Calls or Downtime Needed With its parallel PDU, the SU20KRTAA with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation. When making repairs or replacing a battery, no lengthy service calls or downtime are necessary. Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring Front-panel LEDs indicate line power, online mode, bypass mode, on-battery, charger and AC output status at a glance. The LCD readout with scroll controls supports visual monitoring of a variety of control options to support advanced UPS settings and configurations. The panel rotates for comfortable viewing in rack-mount or tower configuration. Optional WEBCARDLX Network Interface Offers 24/7 Access An accessory slot accommodates the optional Java-free HTML5-based WEBCARDLX interface, which enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads, power loss and downtime. Advanced Communications Ports USB and DB9 ports (cables are included) enable data-saving unattended shutdown of connected systems when used with Tripp Lite’s free downloadable PowerAlert® software. Capabilities include detailed monitoring of load levels, self-test data and utility power conditions. Versatile Installation Options Hardware is included for mounting the 20kVA UPS system in 12U of space in an EIA-standard 19-inch 4-post rack. Use four optional 2POSTRMKITHD kits for 2-post rack mounting or two optional 2-9USTAND kits for mounting in an upright tower position. TAA-Compliant UPS for GSA Schedule Purchases The SU20KRTAA is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases. 2-Year Warranty, $250K Ultimate Lifetime Insurance and Environmentally Responsible Design The SU20KRTAA comes with a 2-year warranty and $250,000 of Ultimate Lifetime Insurance for any connected components damaged by a power surge (U.S., Canada and Puerto Rico only). It’s manufactured in compliance with strict RoHS specifications, reflecting Tripp Lite’s commitment to environmental responsibility.
Products specifications
Attribute nameAttribute value
Master (outer) case width40.3"
Master (outer) case weight601 lbs
Master (outer) case length51"
Master (outer) case height36"
Depth33"
Rack mount kitY
Output voltage regulation+/- 2 %
USB port typeUSB Type-B
Country of OriginTaiwan
Housing MaterialSteel
Emergency Power Off (EPO)Y
Input Frequency50/60 Hz
Display TypeLCD
Power factor0.9
UPS topologyDouble-conversion (Online)
Serial interfaceY
Output frequency50/60 Hz
Number of input phases1
EMI/RFI noise filteringY
Cold startY
Crest factor3:1
Emergency Power Off (EPO) connectorY
Battery weight159 lbs
Design
Form factorRackmount
Technical details
Product colorBlack
Sustainability certificatesRoHS
Sustainability complianceY
Features
Output power18000 W
Efficiency100000 h
Rack capacity12U
Built-in fanY
Noise level60 dB
Surge energy rating2565 J
Input operation voltage (min)200 V
WaveformPure sine
Cooling typeActive
LED indicatorsY
Audible alarm(s)Y
Input operation voltage (max)240 V
Output operation voltage (min)200 V
Output operation voltage (max)240 V
Packaging data
Package width40.3"
Package depth51"
Package height36"
Package weight601 lbs
Logistics data
Quantity per master (outer) case1 pc(s)
Packaging content
Cables includedRS-232, USB cable
ManualY
Ports & interfaces
AC outlet typesC19 coupler, NEMA L6-30R
Serial ports quantity6
AC outlets quantity-30 - 50 °C
RS-232 ports2
USB 2.0 ports quantity2
Power plugHardwire
USB portY
Power
Maximum current125 A
Output power capacity20 kVA
Power protection featuresOver voltage, Under voltage
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Storage relative humidity (H-H)0 - 95 %
Operating altitude0 - 118110.2"
Battery
Typical backup time at full load4.3 min
Typical backup time at half load12.5 min
Battery technologySealed Lead Acid (VRLA)
Hot-swap batteryY
*
*
*
Products specifications
Attribute nameAttribute value
Master (outer) case width40.3"
Master (outer) case weight601 lbs
Master (outer) case length51"
Master (outer) case height36"
Depth33"
Rack mount kitY
Output voltage regulation+/- 2 %
USB port typeUSB Type-B
Country of OriginTaiwan
Housing MaterialSteel
Emergency Power Off (EPO)Y
Input Frequency50/60 Hz
Display TypeLCD
Power factor0.9
UPS topologyDouble-conversion (Online)
Serial interfaceY
Output frequency50/60 Hz
Number of input phases1
EMI/RFI noise filteringY
Cold startY
Crest factor3:1
Emergency Power Off (EPO) connectorY
Battery weight159 lbs
Design
Form factorRackmount
Technical details
Product colorBlack
Sustainability certificatesRoHS
Sustainability complianceY
Features
Output power18000 W
Efficiency100000 h
Rack capacity12U
Built-in fanY
Noise level60 dB
Surge energy rating2565 J
Input operation voltage (min)200 V
WaveformPure sine
Cooling typeActive
LED indicatorsY
Audible alarm(s)Y
Input operation voltage (max)240 V
Output operation voltage (min)200 V
Output operation voltage (max)240 V
Packaging data
Package width40.3"
Package depth51"
Package height36"
Package weight601 lbs
Logistics data
Quantity per master (outer) case1 pc(s)
Packaging content
Cables includedRS-232, USB cable
ManualY
Ports & interfaces
AC outlet typesC19 coupler, NEMA L6-30R
Serial ports quantity6
AC outlets quantity-30 - 50 °C
RS-232 ports2
USB 2.0 ports quantity2
Power plugHardwire
USB portY
Power
Maximum current125 A
Output power capacity20 kVA
Power protection featuresOver voltage, Under voltage
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Storage relative humidity (H-H)0 - 95 %
Operating altitude0 - 118110.2"
Battery
Typical backup time at full load4.3 min
Typical backup time at half load12.5 min
Battery technologySealed Lead Acid (VRLA)
Hot-swap batteryY